{"title":"Protectors \/ Breakers \/ Relays","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eProtect your water pump and control box with proper sized circuit protectors.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"18a-20a-main-breaker-overload-protector-for-3hp-single-phase-control-box","title":"18A - 20A Main Breaker \/ Overload Protector for 3HP Single Phase Control Box","description":"\u003cp\u003e18A-20A Main Breaker (Overload Circuit Protector) for 3HP Single Phase Control Box. Not including lead wires. This is the one near the center at the bottom of the control box. The secondary protector is the one near the side, 9A-10A, which can't likely go wrong.\u003c\/p\u003e \u003cp\u003e\u003cspan class=\"a-list-item\"\u003e\"Trip Free\" design, do NOT hold \"ON\" it during fault current condition!!\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan class=\"a-list-item\"\u003eAvoid to install the control box in direct sun or in a hot area.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eProtectors are made to protect the abnormal situation. When it tripped, it is most likely that there is a reason causing high amp draw for it to trip. To reset it, You must follow this process:\u003c\/p\u003e \u003cp\u003e1) Shut off the main power.\u003c\/p\u003e \u003cp\u003e2) Wait for 30 second for the protector to cool down.\u003c\/p\u003e \u003cp\u003e3) Turn on the power to try the pump. Do NOT force it to reset while the power is on!\u003c\/p\u003e \u003cp\u003eIf the tripping is causing by a power surge, lightning or temporary low voltage, after resetting the protector, the pump should work again.  \u003c\/p\u003e \u003cp\u003eIf the protector trips immediately or in less than 10 second after power on, there may be a short circuit in the drop wire or the pump is locked up. Do NOT push the reset while the power is on.\u003c\/p\u003e \u003cp\u003eIf the protector continues to trip several times in a month, you may change it. In the meantime check for the pressure tank's pre-charged pressure, 2-3 PSI lower than the cut-on pressure set for the pressure switch. Check if there is air got in the system due to leaky pipe, or broken tank bladder. Make sure an external check valve is installed under water level if a pressure tank is used. \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023209885976,"sku":"18A","price":13.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/16A__82053.jpg?v=1777849286"},{"product_id":"14a-15a-main-breaker-overload-protector-for-2hp-single-phase-control-box","title":"14A\/15A Main Breaker \/ Overload Protector for 2HP Single Phase Control Box","description":"\u003cp\u003e14A-15A Main Breaker (Overload Circuit Protector) for 2HP Single Phase Control Box. This is the one near the center at the bottom of the control box. The secondary protector is the one near the side, 8A-10A, which will not likely go wrong.\u003c\/p\u003e \u003cp\u003e\u003cspan class=\"a-list-item\"\u003e\"Trip Free\" design, do NOT hold \"ON\" it during fault current condition!!\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eProtectors are made to protect the abnormal situation. When it tripped, it is most likely that there is a reason causing it to trip. To reset it, You must follow this process:\u003c\/p\u003e \u003cp\u003e1) Shut off the main power.\u003c\/p\u003e \u003cp\u003e2) Wait for 30 second for the protector to cool down.\u003c\/p\u003e \u003cp\u003e3) Turn on the power to try the pump. Do NOT force it to reset while the power is on!\u003c\/p\u003e \u003cp\u003eIf the tripping is causing by a power surge, lightning or temporary low voltage, after resetting the protector, the pump should work again.  \u003c\/p\u003e \u003cp\u003eIf the protector trips immediately or in less than 10 second after power on, there may be a short circuit in the drop wire or the pump is locked up. Do NOT push the reset while the power is on.\u003c\/p\u003e \u003cp\u003eIf the protector continues to trip several times in a month, you may change it. In the meantime check for the pressure tank's pre-charged pressure, 2-3 PSI lower than the cut on pressure set for the pressure switch. Check if there is air got in the pump due to leaky pipe, or broken tank bladder. Make sure an external check valve is installed under water level if a pressure tank is used. \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023209951512,"sku":"14A","price":12.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/13A__80431.jpg?v=1777849293"},{"product_id":"10a-11a-breaker-overload-protector-for-1-5hp-single-phase-control-box","title":"10A - 11A Breaker \/ Overload Protector for 1.5HP Single Phase Control Box","description":"\u003cp\u003e10A Breaker (Overload Circuit Protector) for 1.5HP Single Phase Control Box\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023210705176,"sku":"10A","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/13A__04954.jpg?v=1777849331"},{"product_id":"7a-8a-breaker-overload-protector-for-3-4hp-1hp-control-box","title":"7A\/8A Breaker \/ Overload Protector, for 3\/4HP \/ 1HP Control Box","description":"\u003cp\u003e7A\/8A Breaker (Overload Circuit Protector). To be used in the 3\/4HP or 1HP control box as the main protector and in a 2HP pump box as a secondary protector.\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023210967320,"sku":"8A","price":9.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/13A__45548.jpg?v=1777849342"},{"product_id":"voltage-relay-for-tuhorse-0-75hp-1hp-1-5hp-and-up-to-2hp-control-box-single-phase-230v","title":"Voltage Relay for Tuhorse 0.75HP 1HP 1.5HP and up to 2HP control box, single phase 230V","description":"\u003cp\u003eRepair part\u003c\/p\u003e \u003cp\u003eVoltage Relay for Tuhorse 3\/4HP, 1HP, 1-1\/2HP  and 2HP control box, single phase 230V. \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023211360536,"sku":"Relay35","price":22.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/Relay1__75754.jpg?v=1777849360"},{"product_id":"9a-10a-breaker-overload-protector-for-3hp-control-box-secondary","title":"9A - 10A Breaker \/ Overload Protector for 3HP Control Box Secondary","description":"\u003cp\u003e9A-10A Secondary Breaker (Overload Circuit Protector) for 3HP Single Phase Control Box. This is the one near the side at the bottom of the control box. If you need the one near the center, thich is the main protector, buy the 17A for 3HP. \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023211458840,"sku":"9A","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/16A__94992.jpg?v=1777849364"},{"product_id":"230v-contactor-for-tuhorse-10hp-control-panel","title":"230V Contactor for Tuhorse 10HP Control Panel","description":"\u003cp\u003eThis relay is for a 230V 3-phase 10HP control panel. It has a 230V coil.  For 208V 3-phase, user must let us know to ship a 208V relay instead. The prices for 230V or 208V are the same.\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023211786520,"sku":"Contactor10HP","price":50.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/Relay__34954.jpg?v=1777849373"},{"product_id":"230v-contactor-for-tuhorse-3hp-control-panel","title":"230V Contactor for Tuhorse 3HP Control Panel","description":"\u003cp\u003eThis relay is for a 230V 3-phase 3HP control panel. It has a 230V coil.  For 208V 3-phase, user must let us know to ship a 208V relay instead. The prices for 230V or 208V are the same.\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023215522072,"sku":"Contactor3HP","price":35.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/Relay__67434.jpg?v=1777849540"},{"product_id":"230v-contactor-for-tuhorse-5-5hp-control-panel","title":"230V Contactor for Tuhorse 5.5HP Control Panel","description":"\u003cp\u003eThis contactor is for a 230V 3-phase 5.5HP control panel. It has a 230V coil.  For 208V 3-phase, user must let us know to ship a 208V relay instead. The prices for 230V or 208V are the same.\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023219290392,"sku":"Contactor5.5HP","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/Relay__75937.jpg?v=1777849721"},{"product_id":"35a-main-breaker-overload-protector-for-5hp-single-phase-control-box","title":"35A Main Breaker \/ Overload Protector for 5HP Single Phase Control Box","description":"\u003cp\u003e35A Main Breaker (Overload Circuit Protector) for 5HP Single Phase Control Box. Not including lead wires. This is the one near the center at the bottom of the control box. The secondary protector is the one near the side, 20A, which may not likely go wrong.\u003c\/p\u003e \u003cp\u003e\u003cspan class=\"a-list-item\"\u003e\"Trip Free\" design, do NOT hold \"ON\" it during fault current condition!!\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan class=\"a-list-item\"\u003eAvoid to install the control box in direct sun or in a hot area.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003eProtectors are made to protect the abnormal situation. When it tripped, it is most likely that there is a reason causing high amp draw for it to trip. To reset it, You must follow this process:\u003c\/p\u003e \u003cp\u003e1) Shut off the main power.\u003c\/p\u003e \u003cp\u003e2) Wait for 30 second for the protector to cool down.\u003c\/p\u003e \u003cp\u003e3) Turn on the power to try the pump. Do NOT force it to reset while the power is on!\u003c\/p\u003e \u003cp\u003eIf the tripping is causing by a power surge, lightning or temporary low voltage, after resetting the protector, the pump should work again.  \u003c\/p\u003e \u003cp\u003eIf the protector trips immediately or in less than 10 second after power on, there may be a short circuit in the drop wire or the pump is locked up. Do NOT push the reset while the power is on.\u003c\/p\u003e \u003cp\u003eIf the protector continues to trip several times in a month, you may change it. In the meantime check for the pressure tank's pre-charged pressure, 2-3 PSI lower than the cut-on pressure set for the pressure switch. Check if there is air got in the system due to leaky pipe, or broken tank bladder. Make sure an external check valve is installed under water level if a pressure tank is used. \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023220011288,"sku":"35A","price":18.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/Breaker_Overload_35A_small__70140.jpg?v=1777849750"},{"product_id":"voltage-relay-for-tuhorse-3hp-and-5hp-single-phase-230v-control-box","title":"Voltage Relay for Tuhorse 3HP and 5HP, single phase 230V  control box","description":"\u003cp\u003eRepair part\u003c\/p\u003e \u003cp\u003eVoltage Relay for Tuhorse 3HP and 5HP control box, single phase 230V. \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023220044056,"sku":"Relay50","price":23.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0978\/4492\/0600\/files\/Relay1__63184.jpg?v=1777849752"},{"product_id":"230v-contactor-for-tuhorse-2hp-3hp-single-phase-1-phase-deluxe-control-box","title":"230V Contactor for Tuhorse 2HP\/3HP single phase(1-Phase) Deluxe Control Box","description":"\u003cp\u003eThis Contactor (relay) is for Tuhorse 230V 1-phase 2HP\/3HP Deluxe Control Box.  It is rated 22A max in 240VAC. It has a 24V Magnetic Coil. \u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023220437272,"sku":"Contactor3HP22A","price":35.0,"currency_code":"USD","in_stock":true}]},{"product_id":"230v-to-24v-transformer-for-tuhorse-deluxe-control-boxes-of-2hp-3hp-5hp","title":"230V to 24V Transformer for Tuhorse Deluxe Control Boxes of 2HP 3HP 5HP","description":"\u003cp\u003eThis transformer is a repair part for Tuhorse 1-Phase Deluxe Control Boxes from 2HP to 5HP.\u003c\/p\u003e \u003cp\u003eInput = 230V AC\u003c\/p\u003e \u003cp\u003eOutput = 24V AC\u003c\/p\u003e \u003cp\u003eMaximum wattage 25 Watts\u003c\/p\u003e \u003cp\u003eThe Output AC 24V is for driving the contactor coil in the control box.\u003c\/p\u003e","brand":"OEM","offers":[{"title":"Default Title","offer_id":52023220666648,"sku":"Transformer23024","price":29.0,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/www.tuhorse.us\/collections\/protectors-breakers-relays.oembed","provider":"Tuhorse Pumps","version":"1.0","type":"link"}